On eBay Now...

Olympus Omniscan MX 32:128-PR Phased Array Flaw Detector - Zetec Waygate Eddyfi For Sale

Olympus Omniscan MX 32:128-PR Phased Array Flaw Detector - Zetec Waygate Eddyfi
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Olympus Omniscan MX 32:128-PR Phased Array Flaw Detector - Zetec Waygate Eddyfi:
$19999.99

Olympus Omniscan MX 32:128PR Phased Array Flaw DetectorStock #240124FIncluded with Sale-Omniscan MX Unit-32:128PR P1 PA Module-Hard Padded Transport Case-Lithium Ion Battery-Charger and AC CableAbout the Unit:
OmniScan MX
With hundreds of units used throughout the world, the R/D Tech OmniScan MX is Olympus NDT\'s most successful modular and portable phased array and eddy current array test unit. The OmniScan family includes the innovative phased array and eddy current array test units, as well as the eddy current and conventional ultrasound modules, all designed to meet the most demanding requirements of NDT.
The OmniScan MX offers a high acquisition rate and powerful software features in a portable, modular mainframe to efficiently perform manual and automated inspections.
Rugged, Portable, and Battery-Operated
The OmniScan is built to work in the harshest field conditions. Its solid polycarbonatebased casing and rubber bumpers make it a rugged instrument that can withstand drops and shocks.
The OmniScan is so compact and lightweight (only 4.6 kg) that it can be carried easily and handled anywhere inside or outside. The OmniScan will run 6 hours with its two Li-ion batteries.
User InterfaceThe highly legible 8.4-inch real-time display (60-Hz A-scan refresh rate) with a SVGA resolution of 800 x 600 allows you to clearly see defects and details under any light conditions. A scroll knob and function keys make it easy to browse through and select functions. A mouse and a keyboard can also be plugged in for users looking for a more PC-like interface.
Modular PlatformThe instrument is a modular platform that allows you to switch among its different test modules on location. The platform detects the new module and the technology supported so that the configuration and test environment are set automatically.
OmniScan ConnectorThe OmniScan connector has a probe ID feature that enables physical detection and recognition of the probe connected to the mainframe.
• Sets the probe to an appropriate frequency to prevent probe damage. • Sets C-scan resolution of ECA probes. • Loads the correct probe parameters.
Setup and Report • Setup storage compatible with Microsoft Windows (exportable using a CompactFlash card) • Complete report setup including reading configuration, which can be customized using HTML page layout • On-screen interactive help that can be customized for procedure-oriented setups using HTML script templates • Setup preview • Predefined setups Connectivity, Data Storage, and Imaging The OmniScan offers alarm outputs as well as the standard PC ports: USB, SVGA out, and Ethernet. It offers internal data storage capability and extended storage via a CF (CompactFlash) card slot, as well as any USB or network storage.
Typical Applications
Girth Weld InspectionOlympus NDT has developed a circumferential weld inspection system based on the OmniScan PA for the oil and gas industry. This phased array system is qualified to inspect tube with diameters ranging from 48 mm to 1524 mm and thicknesses from 5 mm to 25 mm in compliance with ASME Boiler and Pressure Vessel Code Section V. The semiautomated system offers better inspection speed and detection, and makes the interpretation of the indications significantly easier.
Pressure Vessel Weld InspectionThe combination of time-of-flight diffraction (TOFD) and pulse-echo techniques means that the complete inspection is done in a single scan, significantly reducing the inspection time when compared to conventional raster scanning or radiography. Inspection results are available instantaneously, allowing you to spot a problem with the welding equipment and fix it right away. Based on our vast experience in the nuclear and petrochemical industries, this system includes all the functions that are needed for code-compliant weld inspections.
Scribe Marks Inspection with No Paint RemovalThe Flight Standards Information Bulletin for Airworthiness (FSAW 03-10B), issued on November 2003, report damage along fuselage skin lap joints, butt joints, and other areas of several aircraft caused by the use of sharp tools used during paint and sealant removal. The OmniScan allows the scribe marks inspection to be done without paint removal which is a huge time saver. The inspection is done in a single pass using 60° to 85° SW sector scans. OmniScan PA is now referenced in the Boeing NTM manuals, 737 NDT Manual, Part 4, 53-30-06, July 2005.
Aircraft Fuselage InspectionThe OmniScan ECA (eddy current array) provides the ability to detect hidden corrosion and cracks in multilayer structures. Currently, material loss of 10% of the lap splice thickness can be detected in aluminum at a depth of 0.2 in. Surface and subsurface cracks can be detected in the skin, at the fastener, or at the lap joint edges.
Ultrasound InspectionTime-of-Flight Diffraction (TOFD) Testing TOFD is a technique that uses two probes in pitch-and-catch mode. TOFD detects and records signals diffracted from defect tips for both detection and sizing. The TOFD data is displayed in a grayscale B-scan view. TOFD offers wide coverage and amplitudeindependent sizing compliant with the ASME-2235 code. • One-line scan for full-volume inspection • Setup independent of weld configuration • Very sensitive to all kinds of defects and unaffected by defect orientation
Time-of-Flight Diffraction (TOFD) and Pulse-Echo Testing While TOFD is a very powerful and efficient technique, it suffers from limited coverage resulting from two dead inspection zones: one dead zone is near the surface, the other is at the backwall.
OmniScan UT allows inspections simultaneously combining TOFD with conventional pulse echo. Pulse echo complements TOFD and covers the dead zones. • TOFD inspection • 45° pulse-echo for weld cap inspection on either sides of the weld • 60° pulse-echo for weld root inspection on either sides of the weld
0-Degree Testing (Corrosion and Composite)
The 0-degree testing measures time-offlight and amplitude of ultrasonic echoes reflecting from the part into gates in order to detect and measure defects. • C-scan imaging • Full A-scan recording with C-scan postprocessing
Ultrasound Transducers
Olympus NDT offers thousands of transducers in standard frequencies, element diameters, and connector styles. • Contact and immersion transducers • Dual transducers • Angle beam transducers and wedges • Replaceable delay line transducers • Protected-face transducers • Normal incidence shear wave transducer
Ultrasound Software
Full-Featured C-Scan • Monitors amplitude, peak position, crossing level position, and thickness on each gate • Automatic gate synchronizes from previous gate for higher dynamic range of thickness. • A-scan data storage and C-scan postprocessing capabilities • Optional IF gate for surface following synchronization or measurement gate or TCG/DAC curves • Either positive or negative gate on RF signal (independent for each gate) • Eight alarms completely configurable on single gate events or multiple gate events, filter for n occurrences from one or multiple channels • Customizable color palette for amplitude and thickness C-scan • Adjustable 256-level color palette • 2-axis mechanical encoder with data acquisition synchronization on mechanical movement • Optional data library to access A-scan and/or C-scan on PC for custom processing
Full-Featured B-Scan • Easy-to-interpret cross-sectional view of inspected part • Excellent display of corrosion mapping of boilers, pipes, and storage tanks • Visual identification of the thickness values acquired • Encoded TOFD capability for amplitude-independant defect sizing
Full-Featured A-Scan • Color-selectable A-scan display • Reject mode • Hollow mode • Peak-hold mode (always keeps the signal that shows the maximum amplitude in gate A) • Gate threshold level crossing (changes the color of the curve that is over the gate level) • 60 Hz A-scan refresh rate with overlays of envelope and peak inside the gate
Step-by-Step calibration Wizards
All calibration procedures are guided using step-by-step wizards. • Sound velocity calibration • Wedge delay calibration • TOFD calibration • TCG calibration • Encoder calibration
TOFD Option • B-scan encoded data imaging and storage • Adjustable for brightness and contrast grayscale color palette • 100 MHz A-scan digitizing • TOFD calibration wizard online and offline • Hyperbolic cursor and reading for TOFD sizing • Lateral wave Images Ins: We offer some of the highest prices on your used test equipment. We do partial trade ins or will buy your used equipment outright. An estimated trade in value will be assessed within 24 hours of receiving a value request.
Payment terms: We accept payment prior to shipping by Visa, MasterCard, AMEX, and Paypal (up to $10.000). Businesses and Universities, please call for payment options. Please notify us of method of payment in a timely fashion after the sale has ended. If a buyer has not made any attempt to contact us 7 days after this sale\'s end time we will assume they are forfeiting the sale and the item will no longer be available to them.
International Buyers: We reserve the right to accept or decline international Paypal and credit cards. International shipping is available, but clearing customs will often result in delivery delays.Shipping Terms: Buyer pays for shipping and packaging for this item. International buyers will pay for shipping charges to their country.* Shipping and handling fees are not refundable under any circumstances. In the case of a return, the buyer is responsible for all shipping fees.* Shipping for international buyers will be invoiced separately from the purchased product due to the high expense of shipping charges.* Your phone number is required for shipping purposes, so please provide it with all correspondence.* Please note that calculated shipping is based on UPS. We also reserve the right to ship for the same cost via FedEx or other carriers.
Packaging: All items will be packaged with materials necessary to ensure that the equipment will be adequately protected from the shipping process.response: We appreciate Positive response. We leave response as soon as we get response from you. If you have any problems with the sale, please try to resolve it with us before you leave us a Neutral or Negative response.
Warranty: No warranty is expressed or implied with any unit. All sales include a 3 day right of return (ROR). For any reason, within 72 hours of taking possession of the item, the buyer can return the item for a complete refund minus all shipping costs.
Return Policy: You can return the item for any reason within three days. We put great effort into thoroughly documenting each piece of equipment, typically with very detailed pictures and video clips. We strongly encourage you to study these images closely before you commit to purchasing the item. Please call or email us if you have any questions about anything that you are uncertain about. It is critical that you confirm that this item suites your needs within the three day return policy period. Any returns after two weeks will not be entertained, and we will automatically escalate to . If you choose to open an return case, and we are forced to accept the return, you are responsible for the following:
*Return Shipping and insurance of the item to our Store at the following address:*A Restocking fee of 10% of the purchase price for every week (after the initial 3 day return period) that the item is in your possession, not to exceed two weeks.


Buy Now

Olympus Omniscan MX2 32:128 PR P2 Phased Array Flaw Detector - Panametrics GE UT picture

Olympus Omniscan MX2 32:128 PR P2 Phased Array Flaw Detector - Panametrics GE UT

$29999.99



Olympus Omniscan MX2 32:128 P2 Phased Array Flaw Detector - Panametrics GE PAUT picture

Olympus Omniscan MX2 32:128 P2 Phased Array Flaw Detector - Panametrics GE PAUT

$26999.99



Olympus Splitter - Y-adapter - OmniScan Connector to support two PA probes picture

Olympus Splitter - Y-adapter - OmniScan Connector to support two PA probes

$1200.00



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :