New FLUKE Digital Multimeter F18B+ LED Tester 18B+ Voltmeter replace F18B:
$138.99

Original FLUKE 18B+ Digital MultiMeterwith FREE carrying bag

Origin
China

Attention notice

Our aim is to make you happy and satisfy in our store totally, providing the best product and best service. However, there still some problem happen. Items may be broken during the shipping way or item can not work or compatible with your items suitable. If such anything or any problem happened, please send a message to us by or our email. Firstly and directly, before leaving any response or open any dispute. Please give us the opportunity to resolve the problem. We must guarantee you 100% satisfaction in our store.

If you want buy much quantity or any other type item you like, please contact us by our email, or message we can supply you, and give you much more discount, the super quality and service. Tks!

100% Brand New include battery.

Feature:LED backlight(new)MIN/MAX Mode(new)Larger screen: 1.5 times of F18B's(new)Faster response time than F18B(new)Date Hold Function
Both Auto range and Manual range Selectable
Over range protection for all ranges
Polarity Indication: Indicates negative polarity
Overflow Indication
Sleep Mode /Auto Power off / Low Battery IndicationContinuity Test with Alert
Diode Test
Power Supply: 2 x AA 1.5V Battery

General Specifications:

Maximum Voltage between any Terminal and Earth Ground: 1000 counts,updates 3/secBattery AA,NEDA 15A, IEC LR6Battery hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under deg to 40 deg to 60 degRelative HumidityOperating 10deg to 30deg;≤75% at 30deg to 40degOperating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to accuracy)/deg(<18deg or > 28deg)Fuse protection for current inputs...................440 mA,1000 V Fast Fuse, Fluck specified part only.11A,1000v Fast Fuse, Fluke specified part 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2Electromagnetic 61326-1:PortableElectromagnetic to use in Korea only Class A Equipment(Industrial Broadcasting and Communication Equipment)

ACCURACY SPECIFICATION

Accuracy is specified forone year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy

specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

AC and DC Voltage

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Volts

(40Hz-500Hz)[1]

4.000V

40.00V

400.0V

1000V

0.001V

0.01V

0.1V

1V

1.0 % + 3

1.0 % + 3

1.0 % + 3

AC Millivolts

400.0mV

0.1mV

3.0 % + 3

3.0 % + 3

3.0 % + 3

DC Millivolts

400.0mV

0.1mV

1.0 % + 10

1.0 % + 10

1.0 % + 10

DC volts

4.000V

40.00V

400.0V

1000V

0.001V

0.01V

0.1V

1V

0.5 % + 3

0.5 % + 3

0.5 % + 3

[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.


AC and DC current

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Current μA

(40 Hz-400Hz)

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current Ma

(40Hz – 400Hz)

40.00 m

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current A[1]

(40Hz – 400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current μA

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current mA

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current A[1]

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

[1] 10 A duty cycle < minutes on, 20 minutes off.



Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

Diode Test[1]

2.000V

0.001V

10 %

Temperature

0°C-50.0°C

-55.0°C-0°C

0.1°C

NA

2 % +1°C

2°C

9% +2°C

NA

Resistance

(Ohms)

400.0Ω

4.000KΩ

40.00KΩ

400.0KΩ

4.000MΩ

40.00MΩ

0.1Ω

0.001KΩ

0.01KΩ

0.1KΩ

0.001MΩ

0.01MΩ

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

0.5%+3

0.5%+2

0.5%+2

0.5%+2

0.5%+2

1.5%+3

Capacitance[2]

40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001μF

0.01μF

0.1μF

1μF

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

Frequency[3]

(10Hz -100kHz)

Hz

50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

NA

0.1%+3

0.1%+3

Duty Cycle[2]

1% to 99%

0.1 %

NA

1%typical[4]

1% typical[4]

[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA

[2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).

[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.

[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.


LED Test and Continuity Threshold

Function

Lighting Range

Measurement Range

Resolution

Accuracy

LEDVFTest[1]

(LED Test Socket)

1.00 to 6.00 V

NA

NA

NA

LEDVFTest[2]

(Test leads)

1.00 to 6.00V

1.00 to 6.00V

0.01V

10%[3]

Continuity Threshold

NA

NA

NA

NA

[1]Open circuit test voltage is±12V and short-circuit current is<±5mA(typical)

[2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical)

[3]VFMeasurement with driving current under2.2±0.4 mA

Input Characteristics

Function

Overload Protection

Input Impedance

(Nominal)

Common Mode

Rejection Ratio

Normal Mode

Rejection Ratio

AC Volts

1000V[1]

>60 dB at dc,

50Hz or 60Hz

_

AC Millivolts

400mV

>80dB at dc,

50Hz or 60 Hz

_

DC Volts

1000V[1]

>100dB at dc,

50Hz or 60 Hz

>60dB at

50Hz or 60 Hz

DC Millivolts

400mV

>80dB at ac,

50 Hz or Hz

_

[1]106V Hz Max

STANDARD ACCESSORIES

1. A Pair of Original Test leads
2. F18B+ meter
3. FREE black carrying bag!
4. Original User manual.
5. Batteries.
Please note: This meter is made by FLUKE in China. Everything is original FLUKE product except the carrying bag which is FREE to you.

Note:

Payment:

Please use Paypal for the payment.

Shipping:

The item will be shipped out in 1~3 business days after payment cleared

We’ll notify you the order status and shipping info, the time shipped, the tracking number and the tracking website once it’s been shipped. If you don’t receive the email from us (thru ), please check your spam folder. Please contact your local post office for missing or damaged package. We ship USPS, UPS or Fedex depending on the item.

response:

Once we receive positive response from you we will do the same for you.We want to be sure you are 100% satisfied with your purchase. Please contact us if there are any questions or concerns about your purchase first.

Return:

We offer a 14 days money back guarantee. Please contact us through email before returning any items.

1.We don’t provide return label.

Otherwise,we feel sorry that align="left" class="MsoNormal" style="color: rgb(0, 0, 0); text-indent: -18pt; font-family: Arial; font-size: medium; font-weight: normal; margin-left: 18pt;">3.Please put a paper in the package, on which your ID number, purchase date and reasons for return should be marked.

4.Buyers are responsible for the return shipping costs and 8% open box fee under any circumstances.



Buy Now

New Factory Sealed 25B-D024N114 Allen-Bradley Ser A PowerFlex 525 AC Drive 2023 picture

New Factory Sealed 25B-D024N114 Allen-Bradley Ser A PowerFlex 525 AC Drive 2023

$1100.00



IN US New Sealed Allen-Bradley 25B-D4P0N104 Power Flex 525 1.5kW 2Hp AC Drive picture

IN US New Sealed Allen-Bradley 25B-D4P0N104 Power Flex 525 1.5kW 2Hp AC Drive

$374.00



New AB 2711P-T6C21D8S Allen-Bradley HMI PanelView Plus 7 Graphic Terminal US picture

New AB 2711P-T6C21D8S Allen-Bradley HMI PanelView Plus 7 Graphic Terminal US

$973.00



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :