On eBay Now...

Ozone Detector | USA NIST Calibration For Sale

Ozone Detector | USA NIST Calibration
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Ozone Detector | USA NIST Calibration:
$325.00

Ozone Detector | USA NIST Calibration Brand: FORENSICS DETECTORSModel: FD-90A-O3YouTube: How to Measure Ozone?User Manual: Click HereBlog Article: Click Here Features: ⚛️ DETECT: Professional and accurate OZONE (O3) gas detector, 0 - 20 ppm with 0.1 ppm resolution. Electrochemical sensor. Comes FACTORY-CALIBRATED with NIST traceability. 🌷 ACCURATE: Electrochemical cell sensor with accuracy ≤ ± 5% F.S. and response time: < 30 sec. Zero and span calibration options. 🎆 ALARMS: Adjustable audio, visual, and vibration alarms. Temperature, battery, and time tracking. 💪 STRONG: Shockproof, water-resistant, dustproof, and explosion-proof. Belt clip, charger, cable, and case included. 🕵️ TRUSTWORTHY: 1-year limited warranty. Arrives with a signed and dated calibration certificate. Details: Best in class, professional OZONE (O3) gas detector by FORENSICS has advanced features, a wide range of functions, and the highest quality electrochemical sensor. Comes factory-calibrated. The detection range of O3 is 0 - 20 ppm within 30 seconds at an accuracy < +/- 5% full scale. The detector has a DC 3.7V Li-battery 1500 mAh that allows > 24 hours of continuous use. Advanced features such as temperature detection, alarm recording, alarm setting, time, backlight high-resolution LCD, calibration features, and others are all included. Although ozone gas is used in many applications as a \"sanitizing\" agent, too much can be harmful. Ozone is a reactive gas and a well-documented air pollutant and irritant. The NIOSH immediately dangerous to life or health (IDLH) ozone level is set to 5 ppm or higher. Please note that ozone is unique gas and cannot be calibrated with a calibration gas bottle setup like most gases. Order your ozone calibration service which must be performed in our laboratory with special calibrated equipment necessary to perform ozone gas detector calibration. Included: Gas detector, belt clip, sling, user manual, USB charging cable, calibration cover, and certified calibration certificate. Calibration Options: Calibration Service by Forensics Detectors Calibration Kit:No ozone calibration gas kits exist for ozone since ozone gas must be generated in a special lab. We recommend using our calibration service to calibrate your ozone detector and using our ozone bump tester to validate operation via bump testing. Accessories (DIY sold separately): Ozone Bump TesterPump and ProbeGas Detector Hard CaseGas Detector PouchGas Detector Stand Gas Sensor Replacement (O3) Specifications Ozone Gas (O3) Detection: 0 - 20 ppm with 0.1 ppm resolutionRecommended Calibration Period: 12 monthsGas Sensor Type: Electrochemical Gas SensorGas Sensor Life: 2 - 3 yearsError: ≤ ± 5% F.SResponse Time: < 30 secIndicators: LCD indicates the time, concentration, internal temperature, and battery level Alarm: Indication of alarm, fault, and low voltage with LED, sound, and vibrationStore / Operating Temp: 0 to 122°F (−17.8 to 50°C)Store / Operating Humidity: <95%RHVoltage: DC 3.7V Li-battery 1500 mAhWorking Time: > 24 hoursCharging Time: 3 hoursExplosion Rating: ATEX certified Ex ib IIC T4 GbWeight: 5 oz / 140 g (including battery)Dimensions: 4.3 × 2.3 × 1.7 inches (10.9 × 5.8 × 4.3 cm)Calibration Location (USA): Los Angeles, California, USACalibration Standard (USA): USA NIST Traceable Gas SourceCalibration Location (Europe): Athens, GreeceCalibration Standard (Europe): European NPL Traceable Gas Source Ozone Detector | USA NIST Calibration


Brand: FORENSICS to Measure Ozone?
User Manual: Click Here
Blog Article: Click Here

Features:

  • ⚛️ DETECT: Professional and accurate OZONE (O3) gas detector, 0 - 20 ppm with 0.1 ppm resolution. Electrochemical sensor. Comes FACTORY-CALIBRATED with NIST traceability.
  • 🌷 ACCURATE: Electrochemical cell sensor with accuracy ≤ ± 5% F.S. and response time: < 30 sec. Zero and span calibration options. 
  • 🎆 ALARMS: Adjustable audio, visual, and vibration alarms. Temperature, battery, and time tracking.
  • 💪 STRONG: Shockproof, water-resistant, dustproof, and explosion-proof. Belt clip, charger, cable, and case included.
  • 🕵️ TRUSTWORTHY: 1-year limited warranty. Arrives with a signed and dated calibration certificate.  

Details: Best in class, professional OZONE (O3) gas detector by FORENSICS has advanced features, a wide range of functions, and the highest quality electrochemical sensor. Comes factory-calibrated. The detection range of O3 is 0 - 20 ppm within 30 seconds at an accuracy < +/- 5% full scale. The detector has a DC 3.7V Li-battery 1500 mAh that allows > 24 hours of continuous use. Advanced features such as temperature detection, alarm recording, alarm setting, time, backlight high-resolution LCD, calibration features, and others are all included. Although ozone gas is uséd in many applications as a \"sanitizing\" agent, too much can be harmful. Ozone is a reactive gas and a well-documented air pollutant and irritant. The NIOSH immediately dangerous to life or health (IDLH) ozone level is set to 5 ppm or higher. Please note that ozone is unique gas and cannot be calibrated with a calibration gas bottle setup like most gases. Order your ozone calibration service which must be performed in our laboratory with special calibrated equipment necessary to perform ozone gas detector calibration. 

Included: Gas detector, belt clip, sling, user manual, USB charging cable, calibration cover, and certified calibration certificate.

Calibration Options:  
Calibration Service by Forensics Detectors

Calibration Kit:
No ozone calibration gas kits exist for ozone since ozone gas must be generated in a special lab. We recommend using our calibration service to calibrate your ozone detector and using our ozone bump tester to validate operation via bump testing.

Accessories (DIY sold separately):  
Ozone Bump Tester
Pump and Probe
Gas Detector Hard Case
Gas Detector Pouch
Gas Detector Stand
Gas Sensor Replacement (O3)

Specifications

Ozone Gas (O3) Detection: 0 - 20 ppm with 0.1 ppm resolution
Recommended Calibration Period: 12 months
Gas Sensor Type: Electrochemical Gas Sensor
Gas Sensor Life: 2 - 3 years
Error: ≤ ± 5% F.S
Response Time: < 30 sec
Indicators: LCD indicates the time, concentration, internal temperature, and battery level 
Alarm: Indication of alarm, fault, and low voltage with LED, sound, and vibration
Store / Operating Temp: 0 to 122°F (−17.8 to 50°C)
Store / Operating Humidity: <95%RH
Voltage: DC 3.7V Li-battery 1500 mAh
Working Time: > 24 hours
Charging Time: 3 hours
Explosion Rating: ATEX certified Ex ib IIC T4 Gb
Weight: 5 oz / 140 g (including battery)
Dimensions: 4.3 × 2.3 × 1.7 inches (10.9 × 5.8 × 4.3 cm)
Calibration Location (USA): Los Angeles, California, USA
Calibration Standard (USA): USA NIST Traceable Gas Source
Calibration Location (Europe): Athens, Greece
Calibration Standard (Europe): European NPL Traceable Gas Source

× × × × × × ×
Shipping info

Click the Shipping & Payments tab above the listing description for more info

Click the Shipping & Payments tab above the listing description for more info!

Additional delivery notes

PICK UP OPTION

Sorry, our items are NOT available for pick-up.

PAYMENT

Immediate payment is required upon selecting \"Buy It Now\" or upon checking out through the cart.

We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay.

We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus).

The applicable amount of sales tax charged to an order will be calculated based on the shipment destination\'s state and local sales tax laws.

Thank you for shopping with us on !

Additional Information

No additional information at this time

Ask seller a question

You might also like Low-Level OZONE Detector | 0.01 ppm | NIST Traceable Hydrogen Leak Detector | USA NIST Calibration Oxygen Data Logger Analyzer | USA NIST Calibration Hydrogen Gas Leak Detector | High Range 40,000 ppm | USA NIST Calibration Contact

To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.

Ask seller a question

© Forensics Detectors

Shipping & Payments

Click the Shipping & Payments tab above the listing description for more info

Payment

Accepted Payment Methods

Immediate payment is required upon selecting \"Buy It Now\" or upon checking out through the cart.

We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay.

We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus).

The applicable amount of sales tax charged to an order will be calculated based on the shipment destination\'s state and local sales tax laws.

Thank you for shopping with us on !

Returns

Returns are accepted

Items must be returned within 30 days of the sale ending

Buyer will pay for return shipping.

integration by


Buy Now

Ozone Detector | USA NIST Calibration picture

Ozone Detector | USA NIST Calibration

$325.00



Ozone Gas Detector with Carrying Case, USB Charger, and Accessories picture

Ozone Gas Detector with Carrying Case, USB Charger, and Accessories

$47.35



3.5-inch Smart Sensor Ozone Meter TFT LCD Ozone Analyzer O3 Ozone Detector New picture

3.5-inch Smart Sensor Ozone Meter TFT LCD Ozone Analyzer O3 Ozone Detector New

$91.94



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :