On eBay Now...

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V NEW OEM For Sale

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V NEW OEM
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V NEW OEM:
$40.45

πŸ“‹ Product Overview

Genuine Leviton LB120-AFT 20 Amp, single-pole Combination Arc Fault Circuit Interrupter (CAFCI) breaker with Plug-On Neutral and Thermal Magnetic trip β€” brand new, never installed. Arc fault protection only β€” meeting NEC 210.12 requirements for bedroom, living room, hallway, kitchen, and other living space circuits at 20A. The plug-on neutral design clips directly to the bus bar for a faster, cleaner installation in Leviton plug-on neutral load centers.

⚠️ CONFIRM BEFORE ORDERING 1. Leviton panels only:
β€’ LB120-AFT β†’ fits Leviton plug-on neutral load centers ← THIS LISTING
β€’ NOT compatible with Square D, Siemens, Eaton, or GE panels 2. AFCI only β€” NOT Dual Function:
β€’ LB120-AFT β†’ Arc Fault protection only
β€’ LB120-DFT β†’ AFCI + GFCI combined (dual function β€” different listing)
If you need both AFCI and GFCI, you want the LB120-DFT instead. 3. Plug-On Neutral β€” advantage for remodels and new panels:
β€’ Neutral clips directly to bus bar β€” no pigtail wire needed
β€’ Cleaner panel, faster install, fewer termination points
β€’ Requires a Leviton load center with plug-on neutral bus bar πŸ”– Panel Confirmation:
βœ… Panel is a Leviton Load Center with PON bus bar β†’ LB120-AFT (this listing)
❌ Panel is Square D, Siemens, Eaton, or GE β†’ Not compatible
❓ Not sure? Send us a photo of your panel label β€” we confirm for free πŸ”§ Key Features & Specifications Specification Detail BrandLeviton ModelLB120-AFT Quantity1 Breaker Maximum Amperage20 A Voltage120 VAC Number of Poles1 Trip TypeThermal Magnetic Protection TypeCombination AFCI (Arc Fault Only) AIC Rating10,000 AIC (10kAIC) Neutral ConnectionPlug-On Neutral (No Pigtail) Wire Range#14-10 AWG Copper Compatible PanelsLeviton Plug-On Neutral Load Centers Only NOT CompatibleSquare D, Siemens, Eaton, GE Panels CertificationsUL Listed ConditionNew πŸ” Which Leviton 20A Breaker Do You Need? Model Protection Neutral Amps LB120-AFT ← THIS AFCI only βœ… Plug-On Neutral 20A LB120-DFT AFCI + GFCI Plug-On Neutral 20A LB115-AFT AFCI only Plug-On Neutral 15A LB120-T Standard Plug-On Neutral 20A ⚑ Common Uses & Applications
  • Bedroom circuits β€” NEC 210.12 requires AFCI for all sleeping area 20A circuits
  • Living rooms, hallways, and dining areas requiring AFCI at 20A
  • Kitchen and laundry 20A branch circuits requiring AFCI per local code
  • Single-circuit additions or replacements in Leviton plug-on neutral load centers
  • New construction and remodels with modern Leviton PON panels
  • Replacement for a failed or tripped AFCI breaker in an existing Leviton PON panel
πŸ’Ž What You Get With This Purchase
  • βœ… Genuine OEM Leviton AFCI Breaker β€” New β€” no counterfeit risk, reliable arc fault protection
  • βœ… Thermal Magnetic Trip β€” reliable, time-tested overcurrent protection
  • βœ… Plug-On Neutral β€” No Pigtail β€” faster, cleaner install
  • βœ… Full Model Comparison Chart β€” order the exact right breaker with confidence
  • βœ… Free Compatibility Verification β€” send us your panel model or photo before you buy
  • βœ… 30-Day Return Window β€” if it's not exactly what you need, you can send it back
  • βœ… 24+ Years of Hands-On Electrical Expertise β€” real answers, not a script
βœ… Why Buy From Us

πŸ”Ή 24+ Years of Electrical Expertise
πŸ”Ή 5,000+ Satisfied Customers
πŸ”Ή 100% Positive response

πŸ“¦ Shipping & Returns
  • βœ… FREE SHIPPING - UPS/USPS with tracking
  • βœ… Same-day handling on orders placed before 3 PM EST
  • βœ… Full insurance on all shipments
  • βœ… 30-Day Returns Accepted β€” buyer responsible for return shipping cost
  • βœ… Expedited shipping option available at checkout
⚠️ Installation Notice: Compatible with Leviton plug-on neutral load centers only β€” NOT compatible with Square D, Siemens, Eaton, or GE panels. Requires a panel with a plug-on neutral bus bar. Installation should be performed by a qualified individual in accordance with NEC 210.12 and local electrical codes. πŸ“ž Contact & Support

Not sure if your Leviton panel has a plug-on neutral bus bar? Send us a photo of your panel label β€” we'll confirm the correct breaker for free before you buy.



Buy Now

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V NEW OEM picture

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V NEW OEM

$40.45



Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V picture

Leviton LB120-AFT 20A 1-Pole AFCI Arc Fault Plug-On Circuit Breaker 120V

$27.00



Leviton LB230-T 30A 120/240V Circuit Breakers Pack Of 5 picture

Leviton LB230-T 30A 120/240V Circuit Breakers Pack Of 5

$54.99



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :