On eBay Now...

DC 6V-30V 10A Thermostat Temperature Humidity Controller SHT20 Sensor Module New For Sale

DC 6V-30V 10A Thermostat Temperature Humidity Controller SHT20 Sensor Module New
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

DC 6V-30V 10A Thermostat Temperature Humidity Controller SHT20 Sensor Module New:
$15.08

  • Home
  • Arduino
  • Module
  • Sensor
  • Chips
  • XY-WTH1 Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel.
    Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor

    Features:
    1>. LCD high definition display;2>. Power-down memory function;3>. Real-timedisplaytemperature;4>. Real-timedisplayhumidity;5>. Automatically save parameters;6>. Support UART Set;7>. Support measurement temperature and humidity at the same time;8>. Work status indicator;9>. Working mode is automatically adjusted;10>. Independent of parameters;11>. With case, beautiful and practical;12>. High precision detection;13>. Multiple parameters are displayed simultaneously.
    Parameters:
    1>. Product Name: Humidity Temperature Controller2>. Product Number: XY-WTH13>. Working Voltage: DC 6V-30V4>. Control Load Current: 10A (Max)5>. LCD refresh rate: 0.5 second6>. Sensor: SHT20 Humidity Temperature sensor7>. Temperature range: -20°C~60°C8>. Temperature Control precision: 0.1°C9>. Humidity range: 0%-100%RH10>. Humidity Control precision: 0.1%RH11>. UART Data transmission cycle: 1.0second12>. Size of Controller: 79*43*35mm13>. Size of Sensor probe: 60*30*20mm14>. Length of Sensor cable: 1.0 meter
    Temperature function:
    1>. Automatic recognition of working mode:The module automatically selects the working mode according to the Start Temperature and Stop Temperature.Start Temperature is more than stop temperature, Turn ON cooling mode \'C\'.Start temperature is less than stop temperature, Turn ON heating mode \'H\'.2>. Cooling Mode \'C\':Relay turn ON and Red Indicator turn ON and Refrigeration equipment starts working if connect load when Current Temperature is more than Start Temperature.Relay turn OFF and Red Indicator turn OFF and Refrigeration equipment stops working if connect load when Current Temperature is less than Stop Temperature.3>. Heating mode \'H\':Relay turn ON and Red Indicator turn ON and Heating equipment starts working if connect load when Current Temperature is less than Start Temperature.Relay turn OFF and Red Indicator turn OFF and Heating equipment stops working if connect load when Current Temperature is more than Stop Temperature.4>. Temperature Correction ‘OFE ’ (-10.0~10.0°C):The system may have errors if it works for a long time, it can be corrected by this function.Actual Temperature = Measured Temperature + Calibration Value.Setting method:4.1>. Double-click button \'TM+\' in the normal running interface into Temperature Correctionsetting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.4.2>. Switch to select modified parameters by short press button ‘TM-’.4.3>. Short press button ‘RH+’and ‘RH-’to set the specific value.Support long press.4.4>. After the parameters have been modified, double-click button ‘TM+’to save the data and exit the correction value setting interface.5>. Set Start/Stop Temperature:Keep press button \'TM+\' for 3second in the normal running interface into Start Temperature setting interface.Short press button \'TM+\' or \'TM-\' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.Keep press button \'TM-\' for 3second in the normal running interface into Stop Temperature setting interface.Short press button \'TM+\' or \'TM-\' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.6>. Relay enable (default on):Short press button ‘TM-’in the normal running interface.Turn ON or OFF temperature relay output enable.Screen will display ‘℃’and flashes if If the temperature relay is OFF.
    Humidity function:
    1>. Automatic recognition of working mode:The module automatically selects the working mode according to the Start Humidity and Stop Humidity.Start Humidity is more than stop Humidity, Turn ON dehumidificationmode \'d\'.Start Humidity is less than stop Humidity, Turn ON humidification mode \'E\'.2>. DehumidificationMode \'d\':Relay turn ON and Green Indicator turn ON and Dehumidification equipment starts working if connect load when Current Humidity is more than Start Humidity.Relay turn OFF and RED Indicator turn OFF and Dehumidification equipment stops working if connect load when Current Humidity is less than Stop Humidity.3>. Humidification mode \'E\':Relay turn ON and Green Indicator turn ON and Humidification equipment starts working if connect load when Current Humidity is less than Start Humidity.Relay turn OFF and Green Indicator turn OFF and Humidification equipment stops working if connect load when Current Humidity is more than Stop Humidity.4>. Humidity Correction ‘RH ’(-10.0~10.0%RH):The system may have errors if it works for a long time, it can be corrected by this function.Actual Humidity= Measured Humidity+ Calibration Value.4.1>. Double-click button \'TM+\' in the normal running interface into Temperature Correctionsetting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.4.2>. Switch to select modified parameters by short press button ‘TM-’.4.3>. Short press button ‘RH+’and ‘RH-’to set the specific value.Support long press.4.4>. After the parameters have been modified, double-click button ‘TM+’to save the data and exit the correction value setting interface.5>. Set Start/Stop Humidity:Keep press button \'RH+\' for 3second in the normal running interface into Start Humidity setting interface.Short press button \'RH+\' or \'RH-\' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.Keep press button \'RH-\' for 3second in the normal running interface into Stop Humidity setting interface.Short press button \'RH+\' or \'RH-\' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.6>. Relay enable (default on):Short press button ‘RH-’in the normal running interface.Turn ON or OFF humidity relay output enable.Screen will display ‘%’and flashes if If the temperature relay is OFF.
    Additional Features:
    1>. Set or read data by UART.Parameters such as start temperature/humidity, stop temperature/humidity, temperature/humidity correction, etc. can be set through the UART.2>. Temperature/Humidity real-time reporting.The controller module will report the current temperature/humidity to the terminal equipment by the UART at intervals of 1 second to facilitate data acquisition if the temperature/humidity reporting function is turned ON.3>. Relay enable (default on).If the relay enable is turned off, the relay remains off.That is, the output state will never change, no matter what the measured temperature/humidity is.
    Package Included:
    1PC × DC 6V-30V 10A Temperature Humidity Controller Thermostat XY-WTH1 SHT20 Sensor
    • Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping

    Fill your shipping info

    Refund
    • If the item is defect when you receive it or you are not satisfied with it, please return it within 30 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.

    Am 14.12.2023 hat der Verkäufer die folgenden Angaben hinzugefügt:

    Am 03.02.2024 hat der Verkäufer die folgenden Angaben hinzugefügt:

    Am 25.03.2024 hat der Verkäufer die folgenden Angaben hinzugefügt:



    Buy Now

    2x DC 6V-30V 12V 24V Max 8A Motor PWM Speed Controller W/ Digital Display Switch picture

    2x DC 6V-30V 12V 24V Max 8A Motor PWM Speed Controller W/ Digital Display Switch

    $20.00



    DC6V-30V Brushless Governor Motor PWM Speed Controller With Forward and Reverse picture

    DC6V-30V Brushless Governor Motor PWM Speed Controller With Forward and Reverse

    $10.06



    DC 6V-30V 10A Thermostat Temperature Humidity Controller SHT20 Sensor Module USA picture

    DC 6V-30V 10A Thermostat Temperature Humidity Controller SHT20 Sensor Module USA

    $20.99



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :