  • 3 Channel ECG Sheet:Print directly in 3 channels of data at a time.
  • Auto-analysed Result:300-second rhythm analysis, to help find arrhythmia easier.
  • Adults & Pediatrics:Support ECG tests and analysis for adults & children.
  • Easy Patient Management:Share in PDF, DICOM, DML format, eay transmit patient reports to hospital network.
  • Voice Reminder:Voice and visual reminders for lead-off, low-battery and paper runouts.
  • 15 Language Settings:Multi-language options for operation: English, French, Spanish, Italian and more.
  • Compact & Portable:Light in weight. Handle for carry.
Accuracy and reliability in ECG interpretation
  • Biocare CardioProTM ECG analysis program, proven by CSE/AHA/MIT database
  • 12-lead simultaneous acquisition
  • Complete digital filters and self-adapting filtering
  • Up to 300 seconds of rhythm analysis for easier in arrhythmia locating
  • Applied the latest Minnesota code
Technical Specifications
  • Physical Info
    Device Dimensions:11.1'' x 7.5'' x 2.3'' (281mm x 191mm x 59mm)
    Weight:2.9lb / 1.3kg
    Display:5.0'' TFT LCD full-view display
    Model:Biocare iE300
  • Tech Spec
    Acquisition Mode:Simultaneous standard 12-lead
    Lead Mode:Standard 12 leads
    HRV:Heart Rate Variability acquisition and review
    Patient Type:
    Adults (older than 12 years old);
    Pediatrics (age: 29 days - 12 years old);
    Neonates (infants born less than 28 days)
    Heart Rate Range:30 bpm~300 bpm
    Acquisition Time:10~24 seconds
    Sampling Rate:8,000 samples/second/channel
    Frequency Response:0.01Hz~250Hz
    Alarm Prompt:Patient Cable/Print head/Paper, lead off, AC interference, EMG interference, Baseline wander, and Data overflow, etc.
    Common Mode Rejection Ratio (CMRR):>115dB
    ECG Interpretation:Biocare CardioPro ECG analysis program for adults and pediatrics
    Measurement Parameters:Ventricular Rate, PR Interval, QRS Time Limit, QT/QTC Interval, P/QRS/T Axis, RV5/SV1 Amplitude and RV5+SV1 Amplitude
    Rhythm Analysis:30~300 seconds
    Waveform Freeze:Up to 300 seconds
    Recorder:Thermal Dot Matrix Word Printing System
    Recording Paper:80mm x 20mm, rolled paper
    Record Format:1 x 12, 1 x 12 + 1R, 3 x 4, 3 x 4 + 1R, 3/2
    Record Mode:Auto, Manual, Upload
    Papwr Speed:(5, 6.25, 10, 12.5, 25, 50) mm/s ±5%
  • Power Supply
    DC Power Supply:Rechargeable lithium battery, 11.1V, 2600mAh
    Battery Running Time:3-hour continuous operating
    Battery Charging Time:4 hours
    AC Power Supply:100V-240V, 50Hz/60Hz, 80VA
  • Input & Output
    Communication with Biocare ECG-1000 software on PC with Microsoft Windows XP/Win7/Win8/Win10 operating systems, Vista in 32/64 bits.
    Input:Support external scanner
    Data Storage:1500 records
    Data Format:ECG, XML, JPEG, DICOM, PDF
    USB Port:USB2.0 drive ONLY
Package List
  • Main ECG Unit
  • Patient Lead Wire (1 set)
  • Limb Clamp Clip (1 set)
  • Chest Suction Ball (1 set)
  • ECG Snap-Clip Adapters (10 pieces)
  • Disaposable Electrodes (10 pieces)
  • Power Cables (US & EU Standard)
  • AC Power Adapter
  • Equipotential Grounding Cable
  • z-fold paper Thermal Recording Grid Paper (80mm*20mm)
  • User Manual
  • Qualified Certificate
  • Warranty Card

On Aug 21, 2025 at 09:47:13 PDT, seller added the following information:

On Sep 16, 2025 at 00:20:51 PDT, seller added the following information:



Buy Now

Biocare 12 Lead 6 Channel ECG Machine with Printer 300s Rhythm & HRV ST Analysis picture

Biocare 12 Lead 6 Channel ECG Machine with Printer 300s Rhythm & HRV ST Analysis

$899.00



Biocare 12 Lead 3 Channel ECG Machine with CardioPro™ Printer 300s Rhythm HRV,US picture

Biocare 12 Lead 3 Channel ECG Machine with CardioPro™ Printer 300s Rhythm HRV,US

$689.00



Biocare 12 Lead 3 Channel ECG Machine Interpretive 300s Rhythm & HRV Analysis picture

Biocare 12 Lead 3 Channel ECG Machine Interpretive 300s Rhythm & HRV Analysis

$689.00



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :