On eBay Now...

FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT 4692740 BRAND NEW For Sale

FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT 4692740 BRAND NEW
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT 4692740 BRAND NEW:
$849.00


SERIOUSBUYERS ONLY!
PLEASE READ STORE DETAILSCAREFULLY!

***BRAND NEW***

FLUKE 1587 FC 2 IN 1 INSULATION MULTIMETER W FLUKE CONNECT

PLEASE NOTE FLUKE CHANGED THE PACKAGING & THE CARRYING CASEON THE NEWER ITEMS

Item Details:

Manufacturer:FLUKE

Description from Manufacturer:

The high-performance 2-in-1 insulation DMM

The Fluke 1587 FC Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

The Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:

  • PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

Product highlights

  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test (1587 FC: 0.01 MΩ to 2 GΩ)
  • Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V) for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Rugged, utility hard case allows you to bring everything you need for the job
  • Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation
  • Three-year standard warranty; measurements with TrendIt™ graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing Voltage
  • DC Millivolts
  • AC/DC Milliamps
  • Resistance (0.1 Ω to 50 warranty
  • Remote probe, test leads, alligator clips
  • K-type thermocouple
  • Rugged, utility hard case
  • Auto power off

Sepcifications:

Electrical SpecificationsAC voltage measurementRange600.0 mVResolution0.1 mVAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)6.000 VResolution0.001 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)60.00 VResolution0.01 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)600.0 VResolution0.1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹1000 VResolution1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹¹ 1 kHz bandwidthLow-Pass Filter VoltageRange600.0 mVResolution0.1 mVAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)6.000 VResolution0.001 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)60.00 VResolution0.01 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)600.0 VResolution0.1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)1000 VResolution1 VAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)DC Voltage MeasurementRangeResolutionAccuracy ±(% of Rdg + Counts)6.000 V dc0.001 V±(0.09% + 2)60.00 V dc0.01 V±(0.09% + 2)600.0 V dc0.1 V±(0.09% + 2)1000 V dc1 V±(0.09% + 2)Input impedance10 MΩ (nominal), <100 pFNormal mode rejection ratio>60 dB @ 50 Hz or 60 HzCommon mode rejection ratio>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)Accuracies apply to ± 100% of rangeDC Millivolts MeasurementRangeResolutionAccuracy ±(% of Rdg + Counts)600.0 mVdc0.1 mV±(0.1% + 1)DC and AC Current MeasurementAC 45 Hz to 1000 HzRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(1.5% + 2)¹Burden voltage (Typical)2 mV/mARange60 mAResolution0.01 mAAccuracy ±(% of Rdg+Counts)±(1.5% + 2)¹Burden voltage (Typical)2 mV/mADCRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden voltage (Typical)2 mV/mARange60 mAResolution0.01 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden voltage (Typical)2 mV/mAOverload600 mA for 2 minutes maximumFuse protection for mA input0.44 mA, 1000 V, IR 10 kAAC conversionInputs are ac-coupled and calibrated to the rms value of sine wave inputConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.¹ 1 kHz bandwidthOhms MeasurementRangeResolutionAccuracy +(% of Rdg+Counts)¹600.0 Ω0.1 Ω±(0.9% + 2)6.000 kΩ0.001 kΩ±(0.9% + 2)60.00 kΩ0.01 kΩ±(0.9% + 2)600.0 kΩ0.1 KΩ±(0.9% + 2)6.000 MΩ0.001 MΩ±(0.9% + 2)50.0 MΩ ²0.01 MΩ±(1.5% + 3)Overload protection1000 V rms or dcOpen circuit test voltage<8.0 V dcShort circuit current<1.1 mA¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidityDiode TestDiode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:Accuracy±(2% + 3)Continuity TestContinuity indicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 ΩOpen circuit voltage<8.0 VShort circuit current1.0 mA typicalOverload protection1000 V rmsResponse time>1 m secFrequency MeasurementRangeResolutionAccuracy ±(% of Rdg+Counts)99.99 Hz0.01 Hz±(0.1% + 1)999.9 Hz0.1 Hz±(0.1% + 1)9.999 kHz0.001 kHz±(0.1% + 1)99.99 kHz0.01 kHz±(0.1% + 1)Frequency Counter Sensitivity600.0 mV acV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz100.0 mVV ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz150.0 mVDC Trigger Levels¹ to 20 kHz²NA6.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz1.0 VV ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz1.5 VDC Trigger Levels¹ to 20 kHz²-400.0 mV and 2.5 V60.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz10.0 VV ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz36.0 VDC Trigger Levels¹ to 20 kHz²1.2 V and 4.0 V600.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz100.0 VV ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz-DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V1000.0 VV ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz300.0 VV ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz-DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale inputCapacitanceRangeResolutionAccuracy ±(% of Rdg+Counts)1000 nF1 nF±(1.2% + 2)10.00 μF0.01 μF±(1.2% + 2)100.0 μF0.1 μF±(1.2% ±90 counts)9999 μF1 μF±(1.2% ±90 counts)Temperature MeasurementRangeResolutionAccuracy ±(% of Rdg+Counts)¹-40 ° C to 537 ° C0.1 °C±(1% + 10 counts)-40 ° F to 998 ° F0.1 °F±(1% + 18 counts)¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrumentInsulation SpecificationsMeasurement range0.01 MΩ to 2 GΩTest voltages50, 100, 250, 500, 1000 VTest voltage accuracy+20%, -0%Short-circuit test current1 mA nominalAuto dischargeDischarge time <0.5 second for C = 1 μF or lessLive circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of testMaximum capacitive loadOperable with up to 1 μF loadOutput Voltage50 V (0% to +20%)Display range0.01 to 6.00 MΩResolution0.01 MΩTest current1 mA @ 50 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range6.0 to 50.0 MΩResolution0.1 MΩTest current1 mA @ 50 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)100 V (0% to +20%)Display range0.01 to 6.00 MΩResolution0.01 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range6.0 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)Display range60 to 100 MΩResolution1 MΩTest current1 mA @ 100 kΩResistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)250 V (0% to +20%)Display range0.1 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 250 kΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 250 MΩResolution1 MΩTest current1 mA @ 250 kΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)500 V (0% to +20%)Display range0.1 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 500 kΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 500 MΩResolution1 MΩTest current1 mA @ 500 kΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)1000 V (0% to +20%)Display range0.1 to 60.0 MΩResolution0.1 MΩTest current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range60 to 600 MΩResolution1 MΩTest current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)Display range0.6 to 2.0 GΩResolution100 MΩTest current1 mA @ 1 MΩResistance accuracy ±(% of Rdg + Counts)±(10% + 3 counts)General SpecificationsMaximum voltage applied to any terminal and common1000 VStorage temperature-40 °C to 60 °C (-40 °F to 140 °F)Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)Temperature coefficient0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)Relative humidityNoncondensing0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrumentRadio frequency communication2.4 GHz ISM BandRadio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLEElectromagnetic CompatibilityInternationalIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class AGroup 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.Enclosure protectionIEC 60529: IP40 (non-operating)SafetyIEC 61010-1Pollution Degree 2IEC 61010-2-033CAT IV 600 V / CAT III 1000 VBatteriesFour AA batteries (NEDA 15A or IEC LR6)Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)Weight550 g (1.2 lb)AltitudeOperating2000 mStorage12,000 mOver-range capability110% of range except for capacitance which is 100%Frequency overload protection<107 V HzFuse protection for mA input0.44A, 1000 V, IR 10 kA

Includes:

  • Remote probe
  • Test leads
  • Alligator clips
  • K-type thermocouple
  • Hard case
  • User documentation
Condition:NEW

sale Details:

Shipping:
  • All domestic packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
  • Free shipping is through most economic option

  • Shipping to Hawaii Puerto RicoAlaskacosts extra, email us for shipping quoteand those shipments will be shipped out via USPS priority mail, unless otherwise stated in the sale or negotiated in emails.
  • Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior offerding.
  • Goods will be dispatched the latest in 2 business days.
  • Goods will be shipped out after the holidays and weekends.
  • No local pick ups accepted at this time, unless otherwise stated in the sale
  • Shipping costs are set at that price to cover some of our costs and packaging and handling fees as well as some of the and paypal fees which add to about 13% of the total end price. Please don\'t email us to negotiate about the shipping costs. We are extremely busy, so we might not answer your emails.
  • Shipping and handling fees are not negotiable, by offerding on this item the buyer agrees to pay for all the shipping costs
  • We ship to any destination in the world.
  • INTERNATIONAL BUYERS: The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
  • California buyers are subject to pay 9% tax.
  • International buyers are responsible for all tax and custom duty charges outside the country.
Payment:
  • U.S. Buyers: Credit cards through PayPal
  • Please note that we can\'t accept direct credit card payments at this time
  • International Buyers: PayPal or Wire
  • Payment is due within 6 days of sale closing. If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on .
Terms & Conditions:
  • After the sale is closed, sale winners should contact us regarding any questions or requests.
  • After the sale is closed, payment should be received within 6 days.
  • Buyer has30 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs.
  • Shipping and handling charges are not returnable
  • Items will be replaced or exchanged in case of DOA
  • If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
  • We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
  • All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
  • Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
Contact Information:Please use message



Buy Now

1587FC FLUKE True RMS Clamp Gauge Brand New Expedited Shipping DHL/FedEX picture

1587FC FLUKE True RMS Clamp Gauge Brand New Expedited Shipping DHL/FedEX

$898.00



Fluke 1587 FC Insulation Testing Multimeter with Probes and Hard Case picture

Fluke 1587 FC Insulation Testing Multimeter with Probes and Hard Case

$499.95



Fluke 1587 FC Digital Insulation Multimeter picture

Fluke 1587 FC Digital Insulation Multimeter

$749.00



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :