On eBay Now...

Electro-Metrics Line Impedance Stabilization Network (LISN) model 7820 10Khz - 3 For Sale

Electro-Metrics Line Impedance Stabilization Network (LISN) model 7820 10Khz - 3
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Electro-Metrics Line Impedance Stabilization Network (LISN) model 7820 10Khz - 3:
$995.00

You are offerding on a LISN by Electro-Metrics corp. Removed from service good to excellent physical condition working and recently calibrated. See below Specs :
Line Impedence Stabilization Network | EM-7820 | 10 kHz – 30 MHz

The Electro-Metrics EM-7820 Line Impedance Stabilization Network (LISN) is a two-channel low pass filter network designed to isolate an electrically operated device from an external power source. The EM- 7820 is used when high frequency conducted measurements are made in accordance with ANSI C63.4 and certain FCC, CISPR and VDE standards.

Applications

When measuring conducted radio interference voltages from line to ground, it is essential to stabilize the line impedance so that repeatable tests can be made at more than one facility.

The Electro-Metrics series LISN’s are designed to meet FCC, ANSI and CISPR standards for conducted emissions measurements. Each LISN is designed to present relatively constant impedance to high frequency signals, which may be present on the power lines, between the device under test and the power source.

SpecificationsElectrical

Frequency Range:10 kHz – 30 MHz
VDE 0876 Specified Curve:±-20%
Power Line Frequency:DC to 400 Hz
25 A Maximum Current
2 Lines
Maximum AC Input:
Line-to-Line:440 VAC
Line-to-Ground:220 VAC
Inductance:50µH / 250µH
Impedance:50 Ohms
Connector(s):
Monitor Ports:Type BNC, female
Power Input/Output:Superior Plug/Socket Receptacles

Mechanical

Length:41.15 cm (16.2”)
Width:27.69 cm (10.9”)
Height:15.57 cm (6.13”)
Weight:9.3 kg (20.5 lbs.)

When the associated measuring equipment is a spectrum analyzer or EMI meter which uses an electronically controlled solid state attenuator, it is recommended that a highpass filter (Electro-Metrics EM-7600 Transient Limiter) be used. This precaution prevents possible damage to the attenuator’s FET semiconductors caused by transients.

PRODUCT SHEET


Buy Now

Electro-Metrics ANS-25/2 LISN Line Impedance Stabilization Network 2588 picture

Electro-Metrics ANS-25/2 LISN Line Impedance Stabilization Network 2588

$600.00



ELECTRO-METRICS (EM) LINE IMPEDANCE STABILIZATION NETWORK Mod 7820 HIGH VOLTAGE picture

ELECTRO-METRICS (EM) LINE IMPEDANCE STABILIZATION NETWORK Mod 7820 HIGH VOLTAGE

$1850.00



ELECTRO-METRICS EM-7820 LINE IMPENDANCE STABILIZATION NETWORK picture

ELECTRO-METRICS EM-7820 LINE IMPENDANCE STABILIZATION NETWORK

$400.00



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :