On eBay Now...

Electricity Voltage Meter Monitor Ammeter Car Tester Capacity resistance Device For Sale

Electricity Voltage Meter Monitor Ammeter Car Tester Capacity resistance Device
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

Electricity Voltage Meter Monitor Ammeter Car Tester Capacity resistance Device:
$31.04

Electricity Voltage Meter Monitor Ammeter Car Tester Capacity resistance Device Description
This document describes the specification of the PZEM-013/015 DC multifunction battery tester, this meter is mainly used to testall kinds of battery\'s voltage, discharge current, discharge power, discharge impedance, internal resistance, capacity, dump energy,energy consumption and running time, and display the measurement data through LCD screen.
PZEM-013: Measuring Range 10A (Built-in Shunt)PZEM-015: Measuring Range 300A (use external shunt, can matched with 50A, 100A, 200A, 300A four kinds of shunt).1. Function description1.1 Voltage1.1.1 Measuring range: 0-200V. (when the test voltage is less than 8V, please use the independent power supply mode)1.1.2 Display format: less than 10V display as: 9.99Vless than 100V display as: 99.9Vgreater than 100V display as: 199V1.1.3 Minimum resolution:0.01V1.1.4 The starting test voltage: 0.05V1.1.5 Measurement accuracy:1%1.2 Current1.2.1 Measuring range: 0-10A. (Type: PZEM-013)0-300A(Type: PZEM-015) can set 50A, 100A, 200A,300A four range depend on the external shunt, the factorydefault is 100A.1.2.2 Display format: less than 1A display as: 999mA<10A display as: 9.99A<100A display as: 99.9A≥ 100A display as: 199A1.2.3 Minimum resolution: 1mA1.2.4 The starting test current: 10mA(Type: PZEM-013)20mA(Type: PZEM-015)1.2.5 Measurement accuracy:1%1.3 Power1.3.1 Measuring range: 0-2000W (Type: PZEM-013)0-60000W(Type: PZEM-015).1.3.2 Display format: < 10W display as: 9.99W< 100W display as: 99.9W< 1000W display as: 999W< 10000W display as: 9.99kW≥ 10000W display as: 19.9kw1.3.3 Minimum resolution: 0.01W1.3.4 The starting test power: 0.1W (Type: PZEM-013)0.2W (Type: PZEM-015)1.3.5 Measurement accuracy:1%1.4 ImpedanceImpedance=Voltage/ Current1.4.1 Measuring range: 0-1000ohm1.4.2 Display format: < 100ohm display as: 99.9ohm≥ 100ohm display as: 999ohmWhen over the test range or the current is zero, it display \"---\"1.4.3 Minimum resolution: 0.1ohm1.4.4 Measurement accuracy:1%1.5 Internal ResistanceInternal resistance= (Full voltage - Bring load voltage) / Bring load current, when the bring load voltage is larger than themaximum voltage, the internal resistance is zero.1.5.1 Measuring range: 0-999 milliohm1.5.2 Display format: 999 milliohm , when over the test range or the current is zero, it display \"---\".1.5.3 Minimum resolution: 1 milliohm1.5.4 Measurement accuracy:1%Note: Before you test the internal resistance, you should preset the full voltage depend on the battery type, after it is fully charged youcan use it to test; if you do not fully charge it, you can set the battery without load voltage is the full voltage, then test; the internalresistance is not a fixed value, the more the battery discharged, the bigger the resistance.1.6 Capacity1.6.1 Measuring range: 0-1000AH1.6.2 Display format: < 1AH display as: 999mAH< 10AH display as: 9.99AH< 100AH display as: 99.9AH< 1000AH display as: 999AH1.6.3 Minimum resolution: 1mAH1.6.4 Measurement accuracy:1%Note: Battery capacity testing is a cumulative process of discharge current versus time, it need some time, the time is depend on thedischarge current; before you test the capacity, you should preset the full voltage and the cut-off voltage depend on the battery type,after it is fully charged you can use it to the discharge test; When the dump energy display blank, it means the discharge is over, thiscapacity display value is the battery\'s capacity.1.7 Dump energyDump energy is display via the battery symbol, totally 10 grids, every grid present 10% energy.Dump energy is calculated via the current battery voltage value, before test you should preset the full voltage and the cut-off voltagedepend on the battery type; every grid voltage = (the highest voltage - the lowest voltage) / 10.1.8 Accumulate energy consumption1.8.1 Measuring range: 0-9999kWh1.8.2 Display format: < 1kWh display as: 999Wh< 10kWh display as: 9.99kWh< 100kWh display as: 99.99kWh< 1000kWh display as: 999.99kWh≥ 1000kWh display as: 9999kWhOver the test range will become zero.1.8.3 Minimum resolution: 1Wh1.8.4 Measurement accuracy:1%Note: 1Wh=0.001kWh=0.001 Kilowatt1.9 Running time1.9.1 Measuring range: 0 ~ 999 hour (without load the time will not accumulate)1.9.2 Display format: 0:00:00 ~ 999:59:59Over the test range will become zero.2. Operating Instructions2.1 Setting the full and cur-off voltage2.1.1 Set the full voltage:Step 1: In the normal display interface(like fig. 1), long press the button until the LCD screen display the interface like fig. 2, thenrelease the button
Step 2: SET character blink present it is the setting status of full / cut-off voltage, long press the button until the LCD screen displaythe interface like fig. 3, then release the button.Step 3: At this time, the battery symbol display full grids energy means the full voltage setting status, factory default the full voltage is020.0V, the numerical code circulation flashing from the low bit to the high bit show that the current setting digit, short press to set thedigit; please pay attention that, as the full voltage setting value has 4 digit, but the numerical code has only 3 digit, So the setting isdivided into two parts: low bit (fig. 3) +high bit (fig. 4). For example, the default full voltage is 020.0V, then the display state is 20.0Vto 020V low and high cyclic switching display. If you need to set the full voltage is 199.0V, then please set the low bit to 99.0V, whenthe cycle reaches the high bit, it will display 099V, and only the highest zero bit flicker to prompt it can be setted. Setting the high bitto 199V represents the full voltage is 199.0V.
2.1.2 Set the Cut-off voltage:Step 1: After you set the full voltage, loner press the button until LCD shows the interface of Fig. 5, then release the button;Step 2: At this time, the battery symbol shows the zero-grid to indicate the cut-off voltage setting state, the default cut-off voltage is016.0V, the setting method is the same as above; the cut-off voltage is 0.8 times of the full voltage by default, after setting the fullvoltage, the cut-off voltage is automatically generated in the relationship of 0.8 times; otherwise, you can reset it;After all the above settings are completed, long press the button until the settings are saved and exit the setting status, restore thenormal display interface.2.2 Current range setting (Only for PZEM-015)
Step 1: In the normal display interface, long press the button until the LCD shows the interface of Figure 2, then release the button,short press the button again switch to the interface to Figure 7, it indicates that this state is the current range setting state.
Step 2: Longer press the button until the LCD shows the interface of Figure 8, then release the button, short press the button again toswitch the current range. This meter provides four current ranges, factory default is 100A, choose the corresponding range accordingto the shunt.Step 3: After the current range setting is completed, long press the button until the settings are saved and exit the setting status, restorethe normal display interface.2.3 Clear the Energy
Step 1: In the normal display interface, long press the button until the LCD shows the interface of Figure 2, then release the button,short press the button again switch to the interface to Figure 9, it indicates that this state is the clearing energy setting state.Step 2: Longer press the button until the data has been cleared and exit the setting status, restore the normal display interface.2.4 Clear the capacity
Step 1: In the normal display interface, long press the button until the LCD shows the interface of Figure 2, then release the button,short press the button again switch to the interface to Figure 10, it indicates that this state is the clearing capacity setting state.Step 2: Longer press the button until the data has been cleared and exit the setting status, restore the normal display interface.2.5 Clear the running time
Step 1: In the normal display interface, long press the button until the LCD shows the interface of Figure 2, then release the button,short press the button again switch to the interface to Figure 11, it indicates that this state is the clearing running time setting state.Step 2: Longer press the button until the data has been cleared and exit the setting status, restore the normal display interface.2.6 Working modeThis meter has two modes: normal display mode and dormant mode. In normal display mode, short press the button to enter thedormant mode, in order to reduce the whole machine power consumption, the backlight and LCD display will be turned off in dormantmode. In dormant mode, short press the button will switch to the normal display mode.Note: The meter will stop all measurement functions in dormant mode, so please do not switch to dormant mode if normalmeasurement is performed.3. Wiring Diagram
4.Dimension Figure (mm)
5. Matters needing attention5.1 This module is suitable for indoor, please do not use outdoor.5.2 Applied load should not exceed the rated voltage, current.5.3 Wiring order can\'t be wrong.6. Other specification6.1 LCD full display figure
6.2 Power consumptionNormal working state: 0.03-1.2 WSleeping state: 0.5mW-0.5WThe power consumption is related to the test voltage value, the higher the voltage,the greater the powerconsumption6.3 Working temperature-20C ~ +60C


Buy Now

Voltage Electricity Tester Volt Detector Test Pen AC Non-Contact Sensor 90-1000V picture

Voltage Electricity Tester Volt Detector Test Pen AC Non-Contact Sensor 90-1000V

$14.99



Voltage Electric Tester Volt Detector Test Pen Non-Contact Sensor AC DC 12-1000V picture

Voltage Electric Tester Volt Detector Test Pen Non-Contact Sensor AC DC 12-1000V

$7.95



Voltage Electricity Tester Volt Detector Test Pen AC Non-Contact Sensor 90-1000V picture

Voltage Electricity Tester Volt Detector Test Pen AC Non-Contact Sensor 90-1000V

$14.95



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :