Dental Mobile Digital X-Ray Film Machine Processor With X-Ray Film Processor:
$869.99

Product introduction

BLX-8Plus

Product Introduction

This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees,located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."

TECHNICAL SPECIFICATIONS

Tube Voltage

60kV

Tube Current

1mA

Time Exposure

1~~9s

High pressure generator

30kHz DC

Rated Power

60w

Focal Spot To Skin Distance

>20CM

Focus Spot Size

0.3mm(TOSHIBA)

AC110V~220V

Supply Frequency

50Hz±1%

Radiation Leakage

<20ugy/h

Battery

24V DC 8000MA

Weight

2KG

Dimensions

25 cm×11..5 cm×17cm (L×W×H)

Reference of the Angles:

'

Tooth

Upper

Lower

1-2

42

-15

3

45

-18

4-5

30

-10

6-8

28

-5

Reference of the time of exposure:

Tooth

Adult

Child

Central & Lateral

0.8-1.2

0.8-1.0

Cuspid & 1st Bicuspid

1.2-1.4

1.0- 1.2

Upper 5,6

1.6-1.8

1.4-1.6

Upper 7,8

3.0-3.5

2.8-3.3.

Lower 5,6

1.8-2.0.

1.6-1.8

Lower 7,8

2.0-2.5

1.8-2.3

Packing List:

Main machine 1pc

Power line 1pc

User manual 1pc


BLX-5


Features:

1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation

scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.

2.) Toshiba 0.3mm x 0.3mm micro-focus tube

3.) No protective operation room is needed when installing the complete machine

4.) Flexible adjustment of position and angle of handpiece

5.) Compact in volume, light in weight, convenient for carrying

6.) Time is adjustable, high contrast of picture, imaging in focus

7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and

the maintenance of the machine

8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and

tests have shown that the radial index is zero. Safety is guaranteed.

9.) Non-film inspection and storage can be realized when corresponding to a sensor

Specifications


Voltage: 110v±10%
Power: 24V 8000MA
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20μgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 60KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 5.5 kg
Dimension: 47 x 42 x 19 cm

Content:


Main Unit x 1
Dental Film Position x 1
English Manual x 1
Warranty Card x 1

LK-C27

Fetures:
1.This portable dental X-ray unit is high frequency machine.
2.The body is small, light weight and nearly no radiation.
3.It has excellent image quality, portable storage, save more space.
4.It uses high frequency and DC international power supply.
5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection.
6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery.
8. It also can connect with sensor, is great convenience.
9. The battery is durable, it can take about 5 hundred images after fully charged.
10. It can be connected with intra-oral digital X-ray imaging system.



Technical Parameter:
Tube voltage: 60KV
Tube current: 1mA
Exposure time: 0.1--2.0s
Frequency: 30KHz
Rate power: 60VA
Distance from skin to cone: 130mm
Tube focus: 0.3mm*0.3mm
Battery: DC14.8V 6400mAh
Output voltage: DC16.8V
Ambient temperature: 5℃~40℃
Relative temperature: <75%RH
Net weight: 2.5KG
Gross weight: 3.5KG
Size(mm): 138*165*185
Package size(mm): 220*240*275

Packing List:
Main body 1pc
User manual 1pc

Operation of the Main Unit

1. Upon receiving, open the box and check the product for possible damage during shipping.

2. Make sure the fittings on the encasement list are packaged within the box.

3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
4. After the Main Unit and ball head are perfectly fit together, in the international standard

electrical source, grounding is strongly recommended.

5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit

will show the fore setting time. Now the equipment is in standby mode.

6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time

as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting

mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when

the time is adjusted the light lamp is off. The equipment is now in standby mode.

7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)

8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.

9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)

10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).

Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.

11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot

lamp is off. Don't keep the main unit long in standby mode.Points for Attention

1.Make sure the angle of film, tooth, and b

all head are properly aligned when taking a picture. Keep them steady until the last step of picturing;

making sure that there is no change in any of their positions.

2.Remember to turn the power offwhen work is done.

3.Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.

4.After turning the power on, wait one minute before taking pictures, this allows the ray to provide a

steady output.

5.The equipment switches into protection mode automatically when the voltage is incorrect. If this

occurs, it will not be able to carry out the normal work of filming.

6.When taking pictures, the EXP button could stop the objection and then the machine goes back to the

preparation mode.

7.Use high quality tooth film and developing liquid to make clear pictures.

8.Handle the ball head gently while in use, so as not to damage the delicate component.

9.Do not pull hard on the cable which connects the ball head to the main unit.

10.The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.

11.We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output

is 0.2-0.5 seconds.

12.If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.

13.Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
14. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
15. Other requests accordance with the scope of the technical parameters.

16.Please read the manual carefully before using.


X-Ray Film Holder

Description:
Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.

Specifications:
Material: plastics
Excellent Sensor Protection
Dental X-ray sensor positioner
For digital sensor with line
the clamp size can be adjusted for different imaging plates
Satisfaction Guaranteed!

Package:
1, (Green) For right maxillary upper premolar/molar and left mandibular
2, (Blue) For left maxillary premolar and right mandibular premolar/molar
3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.

One suit includes 3 Pcs(Left, Right, Upper)


300 Barrier Envelopes SIZE #2

For use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection among the doctors and patients .

300 Barrier Envelopes SIZE #2 for Intra Oral X-Ray ScanX Phosphor Storage Plates

Feature:

1.Reduce Cross-Infection.

2.Keep the Phosphor Storage Plate Clean.

3.Easy to use.

4.Low cost, Disposable Use.

5.Compatible with Scan-X Air Techniques and many other brands!


X-Ray Film Processor

Features:
1. It is use view of the dental film processing design ,can wash 30*40mm single film.
2. The machine is small size ,can be directly placed on the table ,Reliable performance, simple operation ,convenient maintenance.
3. Opreating in the daily light can obtain the best dental image all the same
4. The main components of this product for plastic products, with excellent corrosion resistance and strength ,qualitative light easy to move ,can be used in any solid table.Technical :
Use for film size:30*40mm
The biggest irrigation width:50mm
Medicine tank capacity: enhancement of 250ml,fixing 250ml,250ml water
Washing method: manual
Developing temperature: room temperature
Material: engineering plastic
Net weight:1.5KG
Products size:360*280*310mmNote:
1)The film exposure and development time is too long, all can make the film image density is too high, film black. Too little time to film image density is low ,with lighter film.
2)The film should be uniform in potions cup stir, to ensure that the wash effect.
3)Time limit, potions have certain times and after each use should cover the lid of the medicine cup, depending on the manufacture`s instructions.
4)if have a potion fell into eyes, rinse with plenty of water immediately.Packing list:
Main machine : one set
Three potion 250ML cup



Shipping


The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events).

General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal).

Payment

We accept PayPal only.
The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.

If you are planning on combining your items, please make sure that you wait until ALL sales have ended before you visit the checkout. All items must be paid within 7 days.

response


You response is VERY important to us :)

Please leave us positive response, an positive response will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative response, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.

Returns


Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise.

Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.

Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.

IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers shipping expense.

Contact Us


Serivce is our #1 priority at Dentaltree!

If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.

We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Dentaltree. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!

FAQ
Didn't receive the goods in time?
Our working time is Monday to Friday GMT AM8:30-PM5:30, we will reply your mail as soon as possible during working hours.

Didn't receive goods over three month?
Under normal circumstances, the transport time of the United States is 7-14 days, and about 25 days for Europe,30-35 days for Australia , 50-60 days for South America time.
We hope you can understand the international transit,there are many uncertain factors beyond our control, such as bad weather,detained by the Customs and so on,we will try to help you solve all your problems.

Product damage and warranty policy?
Normal mechanical products are warrantee such as dental handpiece,ultrasonic scaler,curing light and some other product warranty period is 3-6 months.

aFDA StatementThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can offer on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.Seller number:0755-42857928

Device Classification Name:System,X-Ray, Mobile

510(K) Number:K200976

Device Name:SR-8230, SR-8230SPortable X-Ray Unit

Regulation Number:892.172

Classification Product Code:IZL

Date Received:4/13/2020

Decision Date:6/10/2020

Regulation Medical:Specialty Radiology

510k Review Panel:Radiology

Reviewed By Third Party:No

Combination Product:No


On Mar-05-21 at 18:17:16 PST, seller added the following information:



Buy Now

Dental Mobile Delivery Unit Turbine Suction System Air Compressor Rolling Case picture

Dental Mobile Delivery Unit Turbine Suction System Air Compressor Rolling Case

$1055.12



Dental Mobile Delivery Cart Adjustable Treatment Unit System 4H GU-P302S USA picture

Dental Mobile Delivery Cart Adjustable Treatment Unit System 4H GU-P302S USA

$1399.34



Dental Mobile Delivery Unit Air Compressor Suction 4Hole/Folding Chair/Handpiece picture

Dental Mobile Delivery Unit Air Compressor Suction 4Hole/Folding Chair/Handpiece

$1445.48



Popular Tutorials

Alarms and Indicator Circuit diagrams Audio electronic circuits list Circuits for Cars/Motorcycles Computer/PC Hardware Circuits : Design Ideas : Fun/Games Circuits : Signal/Sequence/Misc. Generators : Home/Garden related Circuits : Lights & LED Circuits : Motor Circuits : Music related Circuits : < Oscillator Circuits : Power Supply (PS) Circuit diagrams : Radio,transmitter,receiver circuits : Remote Control Circuit diagrams : Robotics related Circuits : Sensors : Telephone Circuit diagrams : Test & Measurement Circuits :