When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
Function:
1. Bule backlight
2. Show real voltage V
3. Show real current A
4. Show activepower W
5. Show reactive power Var
6. Show power Factory COS
7. Show realFrequency Hz
8. Show Total Energy KWh (can\'t reset to zero)
9. Show Positive KWh (can\'t reset to zero)
10. Show reverse KWh (can\'t reset to zero)
11. Rest Energy KWh ( Can rest to zero)
12. RS485
THCHNICAL SPE CIFICATION
STANDARD IEC 62053-21(IEC61036) MODBUS-RTU
NOMINAL VOLTAGE L+N 230V 50HZ (0.8UN~1.15UN)
BASIC CURRENT(lb2) 5A
MAXIMUM CURRENT 65A,
MINIMUM CURRENT 0.02A
FREQUENCY 50Hz/60Hz
CONSUMPTION <2W/10VA
ACCURACY CLASS 1
DISPLAY 5+1 DIGITS
INTERFACE OPEN COLLECTOR OUTPUT(SO)
18~27V 27mA
IMPULSES IMPULSE LENGTH≥30ms
(as per DIN43684)
SERVICE TEMPERATURE LIMIT:-25°+70°
L.E.D 1 COLOUR
NORMAL OPERATION
PINK FLASHING RATE PROPORTIONAL TO LOAD
(1600imp/kwh )
INSTALLATION
MOUNTING DIN RAIL 35mm
PROTECTION IP20(TERMINAL COVERS INCLUDED)
DISPALY:
INFORMATION
LCD DISPLAY
01
Impulse constant imp/kWh
C 0000
02
Total energy kWh
T00 00000.0
03
Import energy kWh
T01 00000
04
Export energy kWh
T02 -00000
05
Reset energy kWh
EP 00000
06
Real Current A
I 000.00
07
Real voltage V
U 000.00
08
Active power W
P 00000.0
09
Reactive power var
q 00000.0
10
POWER FACTOR COSΦ
PF 0.00
11
Real frequency Hz
F 0.00
12
MODBUS-RUT ID
ID 000
13
DL/T645 high 6 digit ID
H 00000
14
DL/645 low 6 digit ID
L 00000
15
Baudrate
b 0000
RS485 COMMUNICATION BUAD RATE:4800 bps
PROTOCOL: MODBUS OR DL/T645-2007
BACK UP(record the date, when power off)
63A type MCB maximum
WARRANTY
Warranty is 24 month
It is void if seal is removed/damaged.
WIRING DIAGRAM
Noted: Please press theBule button to switch the model type!
1 Real Frequency Hz
Range: 00.00~99.99
2. Reset Energy KWH(Only reset Energycan reset to zero, Total energy can\'t reset to zero)
Range: 00000.0~99999.9
3 Real CURRENT A
4. Power Factor COS
5 Reactive power
6 Real Positive kWh
7Real Reverse kWh
The energymeter is suitble forSolar system, The meter can displayPositive KWh andreverse KWh.
8 Real voltage
9 ActivePower W
10 Total Energy KWh
Noted: Total Energy can\'t reset to zero
(Only reset Energycan reset to zero, Total energy can\'t reset to zero)
11MODBUS-RUT ID
12DL/T645 high 6 digit ID
13DL/645 low 6 digit ID
14Baudrate
RoHS
CE EMC
CE LVD
1PC New SND Contactor LC1N65M5N 65A 220V 50Hz #LJ
$141.00
Gossen Digem Gauge f96x48A 220V 45 65Hz 3,5W
$104.14
110V or 220V Plasma Cutter, 65 Amp Non-Touch Pilot Arc Plasma Cutter Machine, 5/
$392.34
Popular Tutorials
Alarms and Indicator Circuit diagrams